Thermoelectric Measuring Equipment for Perioperative Monitoring of Temperature and Heat Flux Density of the Human Eye in Vitreoretinal Surgery

dc.contributor.authorЗадорожний, Олег Сергійович
dc.contributor.authorУманець, Микола Миколайович
dc.contributor.authorПасєчнікова, Наталія Володимирівна
dc.date.accessioned2025-07-15T10:59:27Z
dc.date.issued2025
dc.description.abstractPerioperative monitoring of the ocular heat transfer is important for increasing the safety of long-term vitreoretinal surgery. The study is aimed at studying new thermoelectric measuring devices for comprehensive perioperative monitoring of ocular temperature and heat fluxes in vitreoretinal surgery. This pilot, open-label, prospective study included 23 patients (23 eyes) with proliferative diabetic retinopathy (PDR) in both eyes. The thermoelectric devices were developed for measuring intraocular temperature in vitreoretinal surgery and for determining the ocular surface temperature (OST) and heat flux (HF) density. In all cases, OST and HF density of both eyes were recorded (before and after surgery). Intraocular temperature and temperature of the irrigation fluid were measured intraoperatively. No complications associated with the perioperative use of thermoelectric temperature and HF sensors were identified during the study. The successful application of thermoelectric temperature and HF sensors, developed specifically for ophthalmological applications, in comprehensive perioperative monitoring of ocular heat transfer in patients with PDR in vitreoretinal surgery was demonstrated for the first time. Further research is needed to confirm the benefits of perioperative temperature monitoring in vitreoretinal surgery, as well as to develop equipment for active management of temperature in surgical practice.
dc.identifier.citationKobylianskyi R, Przystupa K, Lysko V, Majewski J, Vikhor L, Boichuk V, Zadorozhnyy O, Kochan O, Umanets M, Pasyechnikova N. Thermoelectric Measuring Equipment for Perioperative Monitoring of Temperature and Heat Flux Density of the Human Eye in Vitreoretinal Surgery. Sensors [Інтернет]. 7 лют. 2025 [цитовано 15 лип. 2025];25(4):999. Доступно на: https://doi.org/10.3390/s25040999
dc.identifier.doihttps://doi.org/10.3390/s25040999
dc.identifier.urihttps://reposit.institut-filatova.com.ua/handle/123456789/1849
dc.language.isoen
dc.subjectthermoelectric device
dc.subjecttemperature
dc.subjectheat flux
dc.subjectvitreoretinal surgery
dc.subjectproliferative diabetic retinopathy 1. Introduction
dc.titleThermoelectric Measuring Equipment for Perioperative Monitoring of Temperature and Heat Flux Density of the Human Eye in Vitreoretinal Surgery
dc.typeArticle

Файли

Контейнер файлів

Зараз показуємо 1 - 1 з 1
Вантажиться...
Ескіз
Назва:
sensors-25-00999-v2.pdf
Розмір:
2.3 MB
Формат:
Adobe Portable Document Format

Ліцензійна угода

Зараз показуємо 1 - 1 з 1
Вантажиться...
Ескіз
Назва:
license.txt
Розмір:
2.95 KB
Формат:
Item-specific license agreed to upon submission
Опис:

Колекції